2017 - Minilab Help could face closure at the end of the year. Our outgoing running cost and time is no longer being covered by our sponsorship. 
With almost 10,000 members we have grown to be perhaps the worlds largest forum for Mini Lab Help. 
We would now consider the sale of this web site, please contact us if you wish to discuss. 

Jump to content

  • Announcements

    • NeilT

      Mini Lab Help.com For Sale   03/16/2017

      2017 - Minilab Help could face closure at the end of the year. Our outgoing running cost and time is no longer being covered by our sponsorship. 
      With almost 10,000 members we have grown to be perhaps the worlds largest forum for Mini Lab Help. 
      We would now consider the sale of this web site, please contact us if you wish to discuss. 

Dave A

Members
  • Content count

    1
  • Joined

  • Last visited

  1. OK I was a Noritsu tech. here in US I am trying to help a friend QSS3011 RA symptoms when printing multiples i.e. 20 of one or 20 separate images the printing slows bigger gaps between prints then stops and an error 6901-0080 comes up or error 6902-02E0 or both I have switched out the Image Processing PCB 3 times and checked and dressed the Fiber optics lines. Seems like a capacitor is running out I worked for Noritsu for 15 yrs and had my own Lab before that and have never come up with before and by the way I changed out the Memory on the board and on the Mother board. No change.
×