kmoon

Members
  • Content count

    3
  • Joined

  • Last visited

  1. I can't find the Kodak Metallic paper profile anywhere, we have i calibrated under Endura, but it just doesn't work correctly. Any help is appreciated.
  2. Green tint in highlights

    After many failed attempts to correct it, the actual densitometer head was the issue.
  3. We purchased a new calibration card for or QSS 31Pro, but we are still getting a green tint in our grayscales. It is especially noticeable in the highlights. I'll attach a test image compared to our 3800, and you will see what I mean. Is it possible it is an early failing AOM driver? We already had one go bad, but it was way more obvious than this. Our tech seems to think it is the stabilizer tanks holding silver, so he suggested draining, scrubbing and flushing the tanks. Thanks in advance for any help.
×