  1. nope it's not related to paper movement, it's data corrupted. posibility is printer cable, flexible head cable or the worst thing is mainboard failed
    2 points
  2. Probably you use Noritsu software. 06831-00000 means image correction error - process by image correction module failed. 15010-00007 means system error - failed to make an output image. Your image processing module doesn't work. Make EZ controller backup ( EZ controller data management menu ) . Then reinstall EZ controller. The latest EZ controller - version 7.20, QSS printer - version 19, profile data - 4.8.
    2 points
  3. I know 1 but I don't know if he has a visa to enter the United States, he is Mexican
    1 point
  4. davidlam

    Mixing Concerns-V30

    better to have float balls inside the CD replenisher tank to reduce CD oxidation
    1 point
  5. Dave S

    Mixing Concerns-V30

    It won't cause contamination but it could cause under development. Check the colour of the CD in the rep tank, if it has gone black it means it has oxidized so will need to be drained out and fresh CD mixed. If it is a light brown colour it will probably be OK. I would say the BL, Fix and STB should be OK.
    1 point
  6. The paper is the one that is moving and that is why it does that, or the head is hitting the paper
    1 point
  7. Here is an example of a test from 3201. It has a larger step between steps 2-4 and below the value of the second step. Perhaps the problem is that your photos have a slight veil (no bright white).
    1 point
  8. yustas

    Problem frontier lp5700

    As I wrote above - check everything concerning paper movement during exposure. Laser unit does not move the laser beam along the paper. Lab moves the paper using stepping motors, belts, etc. So dig there... Or call out the service engineer and pay him!
    1 point
  9. 1 point
  10. Dboy

    Problem frontier lp5700

    Factors and Actions for E-2592 Message Exposing process failed. If problems persist, consult your technical representative. Factors When the exposure process is not completed: 1. The center memory image exposure fails. 2. The image exposure has been completed, however jammed paper remains in the exposure section. (In this case, W-2406 ”Paper jam occurred between exposure section and distribution entrance section (6).” or W-2447 “Paper jam occurred between distribution entrance section and printer exit section (7).” is displayed at the same time.) Actions 1. Open and close the magazine door so that the printing can be resumed. 2. Open the magazine door, remove the paper, and then close the door as the same countermeasure against paper jamming so that the printing can be resume
    1 point
  11. yustas

    Problem frontier lp5700

    Something stops the paper during exposure if the line is across the paper movement. Check paper advance unit for a faulty rollers and belts.
    1 point
  12. Hope you connected correctly. Even if you use three phase to film processor should be supplied only 240 V ( 3 x 240 V ) . In other words used three voltages between Neutral and Phases ( 1, 2 and 3 ) . If your electrician connected to film processor 380 V ( voltage between phases ) then your film processor was burned. Might be burned power input circuit, power supply ( Alpha ) , or something else. You should ask engineers before connection to three phase circuit. If didn't get information from your Fuji engineers you could ask me. You did not it. Connections should be on instillation manuals. Just need look more carefully. I have FP563SCAL service manual and part list, but if you didn't find information on instillation manual then other manuals will not help also.
    1 point
  13. Yes that X-Rite 890, 891 model densitometer were used before /// correct densitometer model the internal "optical reading head" of this kind of grandfather products are all "internal moulding, non-recovery or almost blind". X-rite USA & worldwide distributor had discontinued these parts long long time ago. Wish you good luck . .. . .
    1 point
  14. good luck to you, Olivia lane !
    1 point
  15. what model ? NOT all X-rite model works on the chemical QC
    1 point
  16. Minilab service

    Arcnet error

    6901-0200 means missing ARCNET connection between printer control pcb and laser control pcb. Can be: missing power supply on laser control pcb bad ARCNET connection on laser control pcb bad ARCNET connection on printer control pcb ( cables, which go to laser control pcb ) not working laser control pcb Check power suppliers on laser control pcb ( 5V on J/P1506 and 12V on J/P1505 ) Clean ARCNET connectors on laser control pcb ( J/P1516 and J/P1517 ) , trim ends of ARCNET cables ( 90 degrees ) and connect ARCNET cables back Clean ARCNET connectors ( J/P212 and J/P213 ) on printer control pcb , trim ends of ARCNET cables ( 90 degrees ) and connect ARCNET cables back If all that will not help then laser control pcb is not working. I have this board, if will need it.
    1 point
  17. Dave S

    Negative Imprints

    It is caused by dirt on the bottom rubber rollers on the processing racks. Normally it is coming from the STB racks, try cleaning the rollers with a toothbrush. Probably you will need to dump the STB solution and wash out the tanks and mix fresh STB.
    1 point
  18. DEAR SIR ITS LOOK LIKE DRYER RACK ROLLERS IS NOT GOOD YOU HAVE TO CLEAN IT
    1 point
  19. PHOTOLABPART.COM

    Dryer Temp

    DRY 1= 45 DRY-2 =55 DRY-3= 50
    1 point
  20. software or RGB curves tell the day-by-day trend but won't tell what actions need to take.... the knowledge / chemistry actions knowhow came from Kodak training to operators
    1 point
  21. that Software can print you day-by-day read-in data (from X-Rite densitometer) to R-B-G graphs on graph paper,,, thus you can see RGB trends to tell what's wrong with which chemistry?
    1 point
  22. kodak in 2 decades ago stil use a Kodak software that runs ONLY on [ Windows 95 ] . They never upgrade the software to run on latter windows.
    1 point
  23. To read control strips need colorimeter ( densitometer ) . They can be with software, or without it. Control strips are optional. Not necessary to use them. To be sure that chemicals are good you can process your test film, where frames are not important. To test film processor film transporting can use some plastic stripes, or blank film.
    1 point
  24. Dave S

    V30 general questions

    The main tank sizes are:- CD 7.6 Litres BL 3.1 Litres FIX 5.4 Litres (Total) STB 5.7 Litres (Total) The sub tanks are connected to the main tanks, so when the sub tanks are full so are the main tanks. The machine only replenishes when films are being processed, the machine will not fill the main tanks from empty. You have to manually mix the chemistry to fill the main working tanks according to the chemical manufacturers mixing instructions. When the waste tanks are full the machine will tell you, you simply empty them by opening one of the 4 taps on the back of the machine. There is 1 waste tap for each chemical.
    1 point
  25. Jorgesaldanha, are you asking how to dance tango ? If yes - you lost. Here is technical forum about minbilabs.
    1 point
  26. Minilab service

    ROS

    Might be you read about different minilab model Need read troubleshooter for Fuji 350, 355, 270. 375. E-2522 means B laser(B-SHG) current exceeded. LD current value limiter is detected. Can be abnormal B Laser(BSHG) menu data, bad connection on connector LDD10, trip CP805 on LDD20 circuit board, LDD20 circuit board malfunction, or B laser head is not working.
    1 point
  27. Numera är det lämpligt att skriva på engelska för att få ett svar.
    1 point
  28. Minilab service

    ROS

    ROS - raster output scanning. VCSEL - vertical cavity surface emitting laser. Probably question is about JROS on Fuji 5xxx. There connected all laser parts, except laser heads and AOM crystals. What doesn't work depends on exact error number. Can be not working polygon, synchronization sensor, fans, shutter, LDD board. or bad connections.
    1 point
  29. Do not understand question. Write in English, if want to get answers.
    1 point
  30. If laser unit with error, then it is not new. Need replace laser unit, or repair it. I have few Fuji 350 laser heads and they work without errors. Write private message, if interested.
    1 point
  31. What ever happened to PMA and the Certified Photographic Counselors ?The kids these days need some basic help with F stops, shutter speeds,ISO,ect. As film comes back there will also be a demand for qualified photo sales people .I have owned my camera store for 45 years and seen the transition from film to digital to phone and its pretty darn hard to get people to pull those pictures down from the cloud to make a print. The one in 50,000 images that does get printed usually goes elsewhere. Today I sell the pentax K-1000, canon AE-1,Minolta 700,Nikon fm series,OM1+2,ect. and feel good about it.Sort of like starting over with a whole new generation of film photographers !