Jump to content

Leaderboard


Popular Content

Showing content with the highest reputation since 09/21/2020 in all areas

  1. 2 points
    hivanov

    Ms01 ver 4.2R available

    Dear copyright-protection, please advise your legal status - Are you part of Fujifilm Company? Or part of legal company that represent them? Who are you? On which behalf are you posting above statements? If you do not come up with your legal status, I am assuming that you are just someone who already stole "the software" and try make more profit by cleaning the competition. Let me also remind you (as lawyer to lawyer - assuming you are such one) that posting anonymous treats over the internet is also punishable by law in many countries
  2. 1 point
    Minilab service

    FP232B CN16L Low Throughput

    Replenishment rates and temperatures can be corrected on maintenance mode 2. Look service manual. There you find all settings.
  3. 1 point
    Minilab service

    Konica DP-2010E - Offline mode

    Here all what I needed. Your minilab and workstation work, but you have not LAN connection between them. Test network on workstation computer. To workstation connect some other computer, where set similar IP ( for example 192.9.200.15 ) and standard mask ( 255.255.255.0 ) . Try to run ping both sides. On workstation computer press Start, run, type " ping 192.9.200.15 -t " and pres Enter. Your workstation computer should see new computer and shouldn't be errors. On other computer press Start, run, type " ping 192.9.200.11 -t " and pres Enter. Your other computer should see new computer and shouldn't be errors. If have errors - try replace LAN cable. There should be Ethernet crossover cable. If still have errors - your workstation LAN card doesn't work. Use PCI Ethernet card and set static address for it ( IP 192.9.200.11 and mask 255.255.255.0 ) . Then run ping again. If all OK - connect workstation computer to minilab and try to run ping again ( ping 192.9.200.51 -t ) . If workstation computer works, but still do not see minilab computer then can be bad network settings on minilab computer, or not working LAN card. On minilab computer installed Linux, so you need to ask someone, who know this system. If on Linux IP and mask correct ( 192.9.200.51 and 255.255.255.0 ) then LAN card doesn't work. Can add PCI - LAN card and enter static address for it ( 192.9.200.51 and 255.255.255.0 ) . To install new card driver and set IP you need ask to help someone, who understand Linux ( RedHat Linux V9.0 ) . On R2 minilab computer and workstation computer used the same motherboard. Sorry, but on these motherboards not working LAN is typical fault. It is easy to add new LAN adapter on workstation ( Windows 2000, or Windows XP ) , but not so easy to do it on Linux computer. Before making experiments use Norton Ghost 11.5.1 ( can find it on Hiren’s Boot CD 10.6 and older ) and make HD image files for minilab computer and workstation. This way you save all and have not risk to destroy something.
  4. 1 point
    alex800

    CrossOver qss37( frontier 7700)

    Problem solved , I replaced the SSR1 relay
  5. 1 point
    Minilab service

    Konica DP-2010E - Offline mode

    What is software version? Probably it is old. New software doesn't start, if do not see LAN connection. Old software starts. Can be many reasons why printer is offline. To say something need to know software version and minilab LCD status.
  6. 1 point
    Look LED1 status on processor relay pcb. If it is dark , but CD temperature goes up then faulty processor relay pcb.
  7. 1 point
    oh wait, i miss the picture you've attached, your problem is with the plate , try cleaning plate, and densitometer, maybe some dust blocked the reading , try to blow it up .
  8. 1 point
    worth to check is paper movement, i had this problem before, plate is new turns out the paper is slipping inside densitometer, so the the densitometer measure the wrong coloumn,sometime it's failed to pull the paper
  9. 1 point
    Minilab service

    CTL20 Upgrade

    LP1500/LP2000 software upgrade to 7.7-0X-030 is on A1 CD for 350/370 version 7.7-0E-201 ( SP-1500/SP-2000 ) and on S9 ( 3.0-0E-511 ) . MS01 version 3.1 and 4.2 for XP have upgrade tools for LP1500/LP2000. Hope there will be the same version. Software can't upgrade ROM version. Need replace chip to have version 2 there.
  10. 1 point
    sisir

    CTL20 Upgrade

    Softwate is already updated, only ROM should be upgraded to ver 2.0 But, if you install FMPC new installation mode, no need to upgrade ROM this moment. Just bypass by selecting cancell while it give message requiring Floppy Disk during installation.
  11. 1 point
    I found a loose wire in the serial connector that plugs into the computer. Now it works fine. Thanks for all of the help everyone!
  12. 1 point
    Minilab service

    Lines on images

    All CCD data stored on CCD board. When you put other CCD you see message that data on HD and CCD board mismatch. Choose transfer CCD data into HD to match them. Just in case before changing CCD make scanner backup. When CCD is new it is supplied with floppy and you should load data from it.
  13. 1 point
    Minilab service

    Lines on images

    Optical magnification calibration is to find correct values for exact scanner zoom . They are to have positions, where zoom should stop to have correct magnification. For these zoom rates on 0347 menu need to make focus calibration ( to have similar focus when zoom is in different positions ) . 0321 menu makes focus only on one zoom rate. Focus on other zoom positions depends how good it was calibrated on 0347.
  14. 1 point
    Minilab service

    Lines on images

    Focusing jig is to make optical magnification calibration (0346 menu) , focus calibration for each zoom rate (0347 menu) , optical axis adjustment (0345 menu) , see carrier inclination (0342 menu) and few other. General focus can be corrected without chart - focus position adjustment (0321 menu) . Focus calibration for each zoom rate need to have good focus with all zoom rates. If magnification calibration missing scanner can't work ( have error ) . Have do these tests, or load settings from backup.
  15. 1 point
    Minilab service

    Lines on images

    PZR_ADJ.BIN is stored on backup. It is one of files inside backup archive ( file In_Unit.001 ) .
  16. 1 point
    Minilab service

    Lines on images

    Probably this .bin file store pixel replacement parameters. These settings can't cause this line. If to scan when selected small print size then micro-movement doesn't work.
  17. 1 point
    There certainly were never any schematics released for the SB-3. With machines of this era everything was on paper manuals, which have long gone. All I have on PDF are the parts list. 99% of the problems with the SB-3 are mechanical issues, broken magnets, worn roller bearings, snapped drive belt, damaged tongues etc. If you have any specific questions I will try to answer them for you.
  18. 1 point
    Minilab service

    dx100 service manual

    Yes, Epson SL-D700 and Fuji DX-100 ( Frontier-S ) have the same hardware, the same errors numbers and the same adjustments. Service utility is different for Fuji and Epson. I have service utility for Fuji and Epson. Also have D700 service manual. Write private message, if need them.
×
×
  • Create New...