  1. Hi Dave and Yustas, Just to close this one out, the waste pipe had a blockage that was making the P2 overflow back into the P1. Cleared it out and 100% back in normal operation. Thanks for your suggestions.
  2. Hello Yustas, Your site has a ver good design, well done. Thank you for the suggestion, I am reading it now.
  3. Thanks Dave, will have a look now.
  4. Hello, I have a well used Fuji Frontier 375 that is making the white un-imaged (blank) parts of the photo paper turn out with a yellow tint / cast. P1, P2, PS drained, cleaned and replaced, Filters replaced. Once chem was replace it was printing white as white again = all good, but over 12 hours of use the yellow tint returned and also black on daily condition test print have now a blue shade. Machine uses Tetnal CP48 replenishers
×